Fast Running Damper Actuator 16nm Modulating

Fast Running Damper Actuator 16nm Modulating
Product Introduction:
Fast Running Damper Actuator 16Nm Modulating
For operation of air control dampers inHVAC system.
Torque: 16Nm
Nominal voltage: AC/DC 24V,,AC 100-240V
Control:0(2)...10VDC/0(4)...20mA
Feedback:0(2)...10VDC/0(4)...20mA
-AS type include 2 axiliary switch.
Send Inquiry
Description
Technical Parameters

Product Introduction

 

Master airflow in large-scale commercial and industrial HVAC systems with Hysen's 16Nm Modulating Damper Actuator. This powerful unit combines high torque output with precise analog control, making it the ideal solution for accurately positioning large dampers (up to 3m²) in Building Management Systems (BMS). By responding to standard 0-10V or 4-20mA signals, it enables infinite variability in damper position, ensuring optimal air balance, pressure control, and energy efficiency in the most demanding applications.

 

Key Features & Benefits

 

High-Torque Precision Control:

Delivers 16Nm of force to reliably operate large, heavy, or high-static pressure dampers, while maintaining precise modulation via analog input signals.

Comprehensive Feedback Loop:

Provides real-time 0-10V or 4-20mA position feedback to the BMS, enabling accurate monitoring, diagnostics, and closed-loop control for critical airflow management.

Optimized 16-Second Operation:

The balanced 16-second full-stroke time ensures accurate positioning for large damper blades without sacrificing system response speed or mechanical integrity.

Dual Voltage & Signal Compatibility:

Available in both AC/DC 24V and AC 100-240V models, seamlessly integrating with a wide range of control systems and global electrical standards.

Industrial-Grade Reliability:

Features a robust IP44 enclosure, manual override, and a wide operating temperature range (-20°C to +50°C) for dependable performance in harsh mechanical room environments.

Advanced System Integration:

Optional auxiliary switches provide additional dry contact points for triggering alarms or ancillary equipment based on damper position, enhancing overall system functionality.

 

Products Description

 

Detailed specifications for our 16Nm Modulating Damper Actuator series are outlined below.

 

Parameter

HY-DMQ16-24(S)

HY-DMQ16-230(S)

Electrical Data

   

Nominal Voltage

AC/DC 24V 50/60Hz

AC 100-240V 50/60Hz

Voltage Range

AC/DC 19.2V - 28.8V

AC 85V - 265V

Power Consumption

12W (Running) / 0.5W (Holding)

12W (Running) / 0.7W (Holding)

Control & Feedback

   

Control Signal

0(2)-10V DC or 0(4)-20mA

0(2)-10V DC or 0(4)-20mA

Feedback Signal

0(2)-10V DC or 0(4)-20mA

0(2)-10V DC or 0(4)-20mA

Functional Data

   

Torque

16 Nm

16 Nm

Running Time (90°)

16 Seconds

16 Seconds

Rotation Angle

0° - 90°

0° - 90°

Physical & Environmental

   

Protection Level

IP44

IP44

Ambient Temperature

-20°C to +50°C

-20°C to +50°C

Shaft Connection

10-20mm round or 10x10-16x16mm square

10-20mm round or 10x10-16x16mm square

 

Model Selection Guide

 

Torque

Running Time

Power Supply

Control/Feedback

Auxiliary Switch

Model Code

16Nm

16S

AC/DC 24V

0-10V/4-20mA

None

HY-DMQ16-24

16Nm

16S

AC/DC 24V

0-10V/4-20mA

2 x SPDT

HY-DMQ16-24S

16Nm

16S

AC 100-240V

0-10V/4-20mA

None

HY-DMQ16-230

16Nm

16S

AC 100-240V

0-10V/4-20mA

2 x SPDT

HY-DMQ16-230S

 

Frequently Asked Questions (FAQ)

 

Q1: What types of applications require a high-torque modulating actuator like this 16Nm model?

This actuator is designed for demanding applications where both precise control and high force are needed. This includes large air handling units (AHUs), variable air volume (VAV) systems with high static pressure, industrial ventilation control, smoke management systems, and large zone dampers in big commercial spaces.

Q2: Why is the 16-second running time beneficial for a high-torque unit?

 A slightly slower running time is optimal for high-torque applications. It reduces the inertial stress on the larger damper blades and linkages during start and stop, minimizing wear and tear and ensuring smoother, more accurate positioning, which extends the lifespan of both the actuator and the damper.

Q3: How does the analog feedback (0-10V/4-20mA) benefit building operators?

Analog feedback provides a continuous signal proportional to the damper's exact angle. This allows the BMS to verify that the damper is in the commanded position, diagnose issues (e.g., a damper that is stuck), and implement advanced control strategies based on real-time airflow data, improving overall system reliability and efficiency.

Q4: Can your actuators be customized for specific project requirements?

Yes, as a manufacturer focused on ODM and OEM partnerships, we frequently customize products. We can discuss options for specific control signal ranges, connectors, cabling, branding, and even modified mounting configurations to suit your unique integration needs.

Q5: What is your typical lead time for large ODM orders?

Lead times vary based on the order volume and the extent of customization. For standard models, we maintain efficient production schedules. We provide specific lead time quotes once we understand your project's scope and requirements.

 

Call to Action (CTA)

 

Power Your Advanced Building Automation Systems

Leverage Hysen's manufacturing expertise for your most demanding precision control projects.

● Request a Project Consultation with our engineering team.

● Download Detailed CAD Files for seamless system integration.

● Get a Competitive Quote for OEM/ODM partnerships and volume orders.

[Contact Us for Custom Actuator Solutions] 

 

Hot Tags: fast running damper actuator 16nm modulating, China fast running damper actuator 16nm modulating manufacturers, suppliers, factory, Fast Running Damper Actuator 16nm Modulating, Fast Running Damper Actuator 8nm Modulating, Fast Running Damper Actuator 16nm On off, Fast Running Damper Actuator 8nm On off, fast running damper actuator

Send Inquiry
img