Your Professional Fire Smoke Actuators Supplier

 

Xiamen Hysen Industrial Co., Ltd. is a well-established manufacturer located in Xiamen, Fujian. We specialize in designing, developing, and producing various types of valves. We strive to provide users with high-quality valve products and reliable after-sales service.


16 Years of Industry Experience
With over 16 years in floor heating systems and thermostats, we provide mature technology, stable product performance, and proven market reliability.

 

Strict Quality Control & Full Testing
All thermostats are produced under the ISO9001 system and fully tested before shipment, ensuring consistent quality and dependable performance for every order.

 

Integrated Manufacturing and Trading Capability
With our own production facilities and a dedicated trading team, we offer efficient communication, flexible order handling, and reliable supply for global customers.

 

 
  • Fire Smoke Actuators 5nm
    Fire smoke actuator 5NmFor operation of air control dampers in HVAC system.Torque: 5NmNominal voltage:AC/DC 24V,AC100-240VControl: ON/OFF-DST type include SAF72thermal sensor
    read more
  • Fire Smoke Actuators 3nm
    Fire smoke actuator 3NmFor operation of air control dampers in HVAC system.Torque: 3NmNominal voltage:AC/DC 24V,AC100-240VControl:ON/OFF-DST type include SAF72 thermal sensor.
    read more
 

Specification

 

 

Feature

Specification HY-DF-SF05-24S(T)

Specification HY-DF-SF05-230S(T)

Nominal Voltage

AC/DC 24V 50/60Hz

AC 100-240V 50/60Hz

Voltage Range

AC/DC 19.2V - 28.8V

AC 85V - 265V

Power Consumption

5W (Running), 3W (Holding)

5W (Running), 3W (Holding)

Torque

5 Newton-meters (Nm)

5 Newton-meters (Nm)

Damper Surface Area

Up to 1.0 m²

Up to 1.0 m²

Running Time

< 70 sec / < 20 sec (Spring Return)

< 70 sec / < 20 sec (Spring Return)

Rotation Angle

Maximum 95°

Maximum 95°

Shaft Dimension

12mm x 12mm (Sleeves for 8mm/10mm available)

12mm x 12mm (Sleeves for 8mm/10mm available)

Ingress Protection

IP54

IP54

Ambient Temperature

-20°C to +50°C

-20°C to +50°C

Weight

< 2.0 kg

< 2.0 kg

 

Key Features of Fire Smoke Actuators
 

Critical Spring-Return Function
In the event of a power failure or fire alarm signal, the actuator automatically returns the damper to its safe, pre-set position (either open or closed) in under 75 seconds, ensuring compliance with smoke control protocols.

 

Dual Voltage Flexibility
Engineered for global applications. Choose from low-voltage AC/DC 24V models for BMS integration or direct AC 100-240V options for simpler installations, reducing the need for additional transformers.

 

Integrated Thermal Sensor Option (DST Type)
Select models include a built-in SAF72 thermal sensor. This provides an added layer of safety by triggering the actuator's return function automatically upon detecting high ambient heat, independent of the main fire alarm panel.

Fire Smoke Actuators 5nm

 

Fire Smoke Actuators 5nm

Robust Protection For Harsh Environments
With an IP54 rating, the actuator is protected against dust and water splashing, making it suitable for installation in plenums, mechanical rooms, and other demanding environments. It operates reliably in temperatures from -20°C to +50°C.

 

Manual Override
A manual override feature allows technicians to easily position the damper manually for testing, maintenance, or during system commissioning without the need for tools.

 

Clear Mechanical Position Indicator
Quickly and reliably see the damper's position (open/closed) at a glance, ensuring system status is always visib

 

Applications of Fire Smoke Actuators
 

Stairwells & Elevator Shafts

Pressurize these escape routes to keep smoke out, ensuring safe evacuation.

Ductwork

In ducts passing through smoke barriers, they close to prevent smoke transfer between floors or areas.

Atria & Large Spaces

Control airflow and smoke movement in vast open areas.

Lobbies & Corridors

Manage air pressure and smoke spread in these critical circulation zones.

 

 

Installation Precautions for Fire Smoke Actuators

Smoke detector placement: When smoke dampers are a part of the installation, detectors should always be installed into the ‌duct.


Heat‍ responsive components: These bi-metals are what make a damper a‍fire damper‌ and, consequently, a crucial element of the combination fire and smoke‍ damper.


Support structures: In certain applications, boards may be used to prop‌ up the damper and keep it in place.

Fire Smoke Actuators 5nm

 

Ordering Process

 

 

1. Inquiry--- Provide us all clear requirements (total qty and package details).
2. Quotation--- Official quotation from with all clear specifications from our professional team.
3. Marking Sample --- Confirm all quotation details and the final sample.
4. Production--- Mass production.
5. Shipping--- By sea or by air.

 

Packaging and Shipping

 

 

Packaging

In standard export cartons, but could be designed as your request.

Shipping

Shipping by sea, by air, by express are acceptable. According to your requirements.

 

Our Factory

 

 

Xiamen Hysen Control Technology Co., Ltd. was established in 2008, with more than 16 years of experience in the field of floor heating systems and thermostat.

p20251014171249270ad.jpg (800×500)

 

 

Our Certificates

 

 

modular-1.webp (248×331)
modular-2.webp (248×331)
modular-3.webp (248×331)
modular-4.webp (248×330)
modular-5.webp (248×332)
modular-6.webp (248×332)

 

FAQ

 

Q: Can you customize shaft sizes or connectors for ODM projects?

A: Absolutely. As an ODM specialist, we regularly customize components like shaft adapters (e.g., providing 8mm or 10mm sleeves), wire lengths, connector types, and even branding to meet our partners' specific requirements and technical drawings.

Q: What certifications do these actuators hold, and are they suitable for international markets?

A: Our manufacturing processes adhere to ISO quality standards, and our actuators are designed to meet key international safety and performance guidelines, including IEC and EN standards. We work closely with our ODM and OEM partners to ensure products meet the specific certification requirements (e.g., CE, UL) for their target markets.

Q: What is the lead time for large-volume ODM orders?

A: For standard large orders, our typical lead time is 2-4 weeks. We maintain stock of popular models to expedite initial samples and smaller batches. For highly customized projects, we provide a precise timeline after reviewing your technical specifications.

Q: Can we request samples to test the performance and quality?

A: Yes, we strongly encourage it. We are confident in our manufacturing quality and welcome international B2B partners to request working samples for performance testing and evaluation before committing to a large bulk order.

Q: What is your warranty policy for these actuators?

A: We stand behind the quality of our products. Our fire smoke actuators come with a standard 24-month warranty against manufacturing defects, giving our distribution partners and their end-users confidence in the product's longevity and reliability.

We're well-known as one of the leading fire smoke actuators manufacturers and suppliers in China. With over 15 years' experience, we warmly welcome you to buy discount fire smoke actuators from our factory. All customized products are with high quality and competitive price.

fire smoke actuators, Fire Smoke Actuators 3nm, Fire Smoke Actuators 5nm
Send Inquiry