Your Professional Fast-running Damper Actuator Supplier

 

Xiamen Hysen Industrial Co., Ltd. is a well-established manufacturer located in Xiamen, Fujian. We specialize in designing, developing, and producing various types of valves. We strive to provide users with high-quality valve products and reliable after-sales service.


16 Years of Industry Experience
With over 16 years in floor heating systems and thermostats, we provide mature technology, stable product performance, and proven market reliability.

 

Strict Quality Control & Full Testing
All thermostats are produced under the ISO9001 system and fully tested before shipment, ensuring consistent quality and dependable performance for every order.

 

Integrated Manufacturing and Trading Capability
With our own production facilities and a dedicated trading team, we offer efficient communication, flexible order handling, and reliable supply for global customers.

 

 
  • Fast Running Damper Actuator 8nm On/off
    Fast Running Damper Actuator 8Nm ON/OFFFor operation of air control dampers in HVAC system.Torque: 8NmNominal voltage:AC/DC 24V,AC100-240VControl: ON/OFF,2/3-Point-DS type include 2 axiliary switch.
    read more
  • Fast Running Damper Actuator 16nm On/off
    Fast Running Damper Actuator 16Nm ON/OFFFor operation of air control dampers in HVAC system.Torque: 16NmNominal voltage:AC/DC 24V,AC100-240VControl: ON/OFF,2/3-Point-DS type include 2 axiliary switch.
    read more
  • Fast Running Damper Actuator 8nm Modulating
    For operation of air control dampers inHVAC system.Torque: 8NmNominal voltage: AC/DC 24V,,AC 100-240VControl:0(2)...10VDC/0(4)...20mAFeedback:0(2)...10VDC/0(4)...20mA-AS type include 2 axiliary switch.
    read more
  • Fast Running Damper Actuator 16nm Modulating
    Fast Running Damper Actuator 16Nm ModulatingFor operation of air control dampers inHVAC system.Torque: 16NmNominal voltage: AC/DC 24V,,AC 100-240VControl:0(2)...10VDC/0(4)...20mAFeedback:0(2)...10VDC/0(4)...20mA-AS type include 2 axiliary
    read more
 

Specification

 

 

Parameter

HY-DFQ16-24(S)

HY-DFQ16-230(S)

Nominal Voltage

AC/DC 24V 50/60Hz

AC 100-240V 50/60Hz

Voltage Range

AC/DC 19.2V - 28.8V

AC 85V - 265V

Power Consumption

12W (Running) / 0.5W (Holding)

12W (Running) / 0.7W (Holding)

Functional Data

 

 

Torque

16 Nm

16 Nm

Running Time (90°)

16 Seconds

16 Seconds

Rotation Angle

0° - 90°

0° - 90°

Control Signal

ON/OFF, 2 or 3-Point

ON/OFF, 2 or 3-Point

Physical & Environmental

 

 

Protection Class

Class III (Safety Low Voltage)

Class II (Double Insulated)

Protection Level

IP44

IP44

Ambient Temperature

-20°C to +50°C

-20°C to +50°C

Sound Level

< 65 dB

< 65 dB

Shaft Connection

10-20mm round or 10x10-16x16mm square

10-20mm round or 10x10-16x16mm square

Weight

< 1.3 kg

< 1.3 kg

 

Key Features of Fast-running Damper Actuator
 

Proportional Analog Control
Receives standard 0-10V DC or 4-20mA control signals to precisely modulate the damper to any position between 0° and 90°, enabling infinite variability in airflow.

 

Real-Time Position Feedback
Provides corresponding 0-10V DC or 4-20mA feedback signal to the controller, confirming the damper's exact position for closed-loop control and system diagnostics.

 

Rapid And Accurate Response
Achieves its full 90° rotation in just 8 seconds, ensuring quick system response to changing demands for temperature or pressure balancing.

Fast Running Damper Actuator(8Nm)

 

Fast Running Damper Actuator(8Nm ON_OFF)

Universal Voltage & Signal Compatibility
Offers models for both low-voltage (AC/DC 24V) and line-voltage (AC 100-240V) applications, accepting the most common industry control signals.

 

Manual Override For Servicing
Integrated push-button override allows technicians to manually position the damper for commissioning, testing, or during system maintenance without needing external tools.

 

Reliable In Diverse Environments
Built with an IP44 rating for protection against dust and water splashes, and operates reliably across a wide temperature range from -20°C to +50°C.

 

Applications of Fast-running Damper Actuator

Healthcare & Research
Maintaining precise room pressure (positive/negative) in hospitals, labs, and cleanrooms to prevent contamination, and controlling fume hoods for safety.

 

Industrial Processes
Regulating airflow in paint rooms, drying, and other manufacturing requiring strict climate/ventilation control for product quality and compliance.

Data Centers

Efficient cooling by managing airflow in Air Handling Units (AHUs) and zones.

General HVAC

Fast response in Variable Air Volume (VAV) systems, heating/cooling circuits, and general ventilation/extraction to optimize comfort and air quality.

Fire & Smoke Control

Used in life safety systems to quickly close dampers in response to smoke or fire signals, preventing spread.

 

 

Installation Steps for the Fast-running Damper Actuator

》Attach the actuator tightly to the damper shaft. Make sure it does not move around.
》Put on the anti-rotation bracket. This stops the actuator from turning when it works.
》Connect the actuator linkage to the damper. Check that it moves easily and does not get stuck.
》Hook up the actuator wires to your control system. Use the wiring diagram in the manual.
》Move the actuator all the way open and closed with control signals. Watch to see if the fail-safe return works right.
》Look at all the connections and brackets. Make sure they are tight and not worn out.
》Try the manual override. Make sure you can move the damper by hand if you need to.
》Check that you can see the position indicators and that they are not faded.

Fast Running Damper Actuator(8Nm)

 

Precautions for Using Fast-running Damper Actuator
 

Give them a regular check-up.
Look over the actuators to spot any damage, wear, and tear, or anything else unusual. While you’re at it, wipe off any dirt, dust, or gunk that may have built up. This keeps things running smoothly and prevents problems.

 

Lube them up.

Moving parts need lubrication to avoid too much friction. Be sure to use the right kind of lubricant recommended by the manufacturer. The wrong stuff could actually hurt the actuators.

 

Recalibrate every so often.
This realigns the actuators so they respond correctly to controls and maintain the right airflow and temperature. It makes up for any natural shifts over time. You may also need to tweak settings based on changes in the environment and system needs.

 

Test and verify.
Run the actuators through their paces regularly to confirm everything is working as it should. Catch any potential issues before they become real problems.

 

Fix problems fast.

If inspections turn up any issues, don’t wait to address them. Something like a worn-out part is a ticking time bomb. Replace it pronto to avoid bigger headaches down the road.

 

Packaging and Shipping

 

 

Packaging

In standard export cartons, but could be designed as your request.

Shipping

Shipping by sea, by air, by express are acceptable. According to your requirements.

 

Our Factory

 

 

Xiamen Hysen Control Technology Co., Ltd. was established in 2008, with more than 16 years of experience in the field of floor heating systems and thermostat.

p20251014171249270ad.jpg (800×500)

 

 

Our Certificates

 

 

modular-1.webp (248×331)
modular-2.webp (248×331)
modular-3.webp (248×331)
modular-4.webp (248×330)
modular-5.webp (248×332)
modular-6.webp (248×332)

 

FAQ

 

Q: What does a damper actuator do in an HVAC system?

A: A damper actuator moves the damper inside air ducts. It helps control how much air goes into each room. This keeps the temperature and air quality just right.

Q: How do you know if your damper actuator is not working?

A: Rooms might feel too hot or too cold. You could hear odd noises from the ducts. If airflow changes or stops, your actuator may need checking.

Q: Can you replace a damper actuator yourself?

A: You can change some actuators if you use the manual and simple tools. For tricky systems or safety dampers, call an HVAC professional.

Q: What is the difference between modulating and on/off actuators?

A: Modulating actuators let you set the damper at any angle. This gives you more control over airflow. On/off actuators only open or close the damper all the way. These are best for simple jobs.

Q: How often should you maintain damper actuators?

A: Check damper actuators at least once a year. Clean moving parts, test manual overrides, and listen for strange sounds. Regular checks help you stop bigger problems.

Q: Are damper actuators energy efficient?

A: Yes, new electric actuators use less energy than old pneumatic ones. You save energy by keeping airflow balanced. Smart actuators help you find leaks or stuck dampers fast.

We're well-known as one of the leading fast-running damper actuator manufacturers and suppliers in China. With over 15 years' experience, we warmly welcome you to buy discount fast-running damper actuator from our factory. All customized products are with high quality and competitive price.

Fast Running Damper Actuator 16nm On off, fast running damper actuator, Fast Running Damper Actuator 8nm Modulating
Send Inquiry
img