NAV SERIES
NAV series electric valve actuator is mainly use with Globe Valve in the HVAC system to regulate the flow of water and steam in response to the demand of a controller.
PRODUCT FEATURE
Complete range from 1000N to 3000N
3 Point floating or Modulating
(0-10VDC or 4-20mA Control Signal Selectable)
Low leakage factor of up to 0.05%
High close-off pressure actuator satisfies demanding requirements of high-rise buildings and high pressure pumping systems
TECHNICAL SPECIFICATION
|
ACTUATING FORCE |
1000N/1800N &3000N |
|
POWER SUPPLY |
AC 24V |
|
FREQUENCY |
50/60 Hz |
|
POWER CONSUMPTION |
II |
|
CONTROL SIGNAL |
See TABLE 1: VALVE CODE NUMBER DESIGNATION |
|
LIFE CYCLE |
60,000 cycle |
|
IP PROTECTION |
IP 42(1000N),IP54(1800N/3000N) |
|
AMBIENT TEMPERATURE |
-20°...50°as per IEC721-3-3 |
|
AMBIENT HUMIDITY |
5..95%rH(non Condensing) |
|
INVENTORY TEMPERATURE |
+70°C as per IEC 721-3-2 |
|
STROKE LENGTH |
Max 20 mm(1000N),Max 42mm(1800N/3000N) |
|
WEIGHT |
See TABLE 2: MAXIMUM CLOSE-OFF PRESSURE (KPA) AND WEIGHT |
|
CERTIFICATION |
CE and ISO 9000 (EN...requirements) |
TABLE 1: VALVE CODE NUMBER DESIGNA TION

|
VALVE ACTUATOR NAV |
NAV = Valve Actuator |
|
POWER SUPPLY |
1 = AC 24 |
|
MODULATING SIGNAL (APPLICABLE FOR MODULATING SIGNAL) |
2 = 0(2)-10 Vdc (Factory Default Setting) / 0(4)-20 mA |
|
ACTUATING FORCE |
10 = 1000N 18 = 1800N 30 = 3000N |
To Order
Specify the code number from the Valve Code Number Selection Guide.
Repair Parts
Available repair parts for NVCF Series Valves include replacement valve bodies and replacement actuators.No other field repairs should be attempted.
TABLE 2: MAXIMUM CLOSE-OFF PRESSURE (KPA) AND WEIGHT
|
TABLE 2: MAXIMUM CLOSE-OFF PRESSURE (KPA) AND WEIGHT |
|||||||
|
MAXIMUM SHUTOFF PRESSURE (KPA) |
WEIGHT |
||||||
|
MODEL |
FORCE (N) |
DN20 |
DN25 |
DN32 |
DN40 |
DN50 |
KG |
|
NAV... - 10 |
500 |
1000 |
680 |
550 |
400 |
270 |
1.2 |
|
MAXIMUM SHUTOFF PRESSURE (KPA) |
WEIGHT |
||||||
|
MODEL |
FORCE (N) |
DN20 |
DN25 |
DN32 |
DN40 |
DN50 |
KG |
|
NAV... - 18 |
1800 |
340 |
150 |
90 |
- |
- |
4.8 |
|
NAV... - 30 |
3000 |
- |
- |
270 |
150 |
90 |
5.0 |
FIGURE 3: ACTUATOR WIRING DIAGRAM

TABLE 3: DIMENSION OF ACTUATOR (mm)

APPLICATION OVERVIEW
The NAV series Electric Valve Actuator features a complete range from 1000N to 3000N actuating force.
They are use with the globe valve to regulate the flow of water or Steam. The Actuator can be ordered with NENUTEC Valve NVCS or NVCF series valves and NTC controller for a complete HVAC solution.
FAQ
Q1: How should damper actuators be installed and maintained?
Installation is simple, with universal mounting brackets and clear wiring diagrams provided. Minimal maintenance is required-just periodic inspection to ensure smooth damper operation.
Q2:How do I troubleshoot a damper actuator that is not working?
Common steps include checking power supply, control signal input, wiring connections, and damper movement. Our technical team provides full support and manuals for troubleshooting.
Q3. Can I request samples before placing a large order?
Yes. We welcome international buyers to test samples of our damper actuators before bulk purchasing.
Q4. Are your damper actuators compatible with different control signals?
Yes. Our actuators support ON/OFF, floating point, modulating control (0–10V or 2–10V DC signals), making them suitable for most HVAC and building automation systems.
Hot Tags: modulating control electric globe valve actuator, China modulating control electric globe valve actuator manufacturers, suppliers, factory, Modulating Control Electric Globe Valve Actuator, 2 Way Flanged End Globe Val, 3 Point Control Electric Globe Valve Actuator, 2 Way Brass Screwed End Globe Valv, Motorised Fan Coil Valve, valve actuator